F2-02da-1. Add to cart More info. F2-02da-1

 
 Add to cart More infoF2-02da-1  Outputs: 16 bit resolution, range: 4-20 mA, current sourcing

2-channel analog output module, 12-bit resolution, ranges: 0-5V, 0-10V, -5 to +5V, -10 to +10V. This document also may not show all models included in the listing. Download 57 AutomationDirect I/O Systems PDF manuals. 3 oz. 00 2600 300 D2-09BDC2-1 $238. The F2-02DA-1L module’s rugged construction and high-quality components ensure reliable and consistent performance even in harsh conditions. 884. Back Shopping Cart (0) Support. 20 mA out 12-bit, ext 12VDC pwr retired F2-02DA-2L 2-ch voltage out 12-bit, ext 12VDC pwr retired F2-02DAS-1 Isolated, 2-ch 4-20mA 16-bit out $255. Module Specifications 8–2 Connecting and Disconnecting the Field Wiring…1--5 - Carnegie. 1. 1 A)We have 1 AutomationDirect F2-04RTD manual available for free PDF download: Installation And I/O Manual . DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. Shopping Cart (0) Login. Slot 3 = F2-04RTD . Reference: PLC1. F2-02DA-1, F2-02DA1, F202DA-1, F202DA1, F2 02DA 1: View It Live Request. 00F2-02DA-1 F2-02DA-2 F2-08DA-1 F2-02DAS-1 F2-04AD2DA F2-04AD-1 F2-04AD-2 F2-04RTD F2-04THM F2-08AD-1 F2-08AD-2 2 Out 2 Out 2 Out 4 Out 2 In / 2 Out 2 In 2 In 3 In 3 In 2 In 2 In 04H 04H 16H 17H 02H 03H 03H 15H 15H 01H 01H. Slot 2 = F2-08AD-1 . 4 VDC Max. vffgaston July 15, 2014, 8:58am 9. For the example above, the I/O configuration for Slave 1 is: Slot 0 = F2-04THM Slot 1 = F2-8AD4DA-1 Slot 2 = F2-08AD-1 Slot 3 = F2-04RTD Slot 4 = D2-12TR Slot 5 = F2-4AD2DA Slot 6 = F2-04AD-2 Slot 7 = F2-04AD-1 Use the addresses shown in the ERM Workbench along with the following table to access the analog I/O with your ERM master. This is a new item, with original packaging and includes a 30 day warranty. m. 자동화제어 및 검사계측 부품, 장비 공급Buy F2-02DA-2 / F2-02DA-2 Facts Engineering Analog Output Module from Distributor Santa Clara Systems. Rev. Thông tin sản phẩm (Koyo F2-02DA-1) Tên sản phẩm: Mô đun Analog (DL-205) 2AO A Koyo – F2-02DA-1. DL205 analog output module, 2-channel, current, 12-bit, output current signal range (s) of 4-20 mA, external 12 VDC required. EN. These modules require wire specific to the signal type. All other specifications are the same. JIC / NFPA Sample Drawing; IEC 60617 Sample Drawing; P&ID PIP Sample Drawing; Hydraulic Sample Drawing; Pneumatic Sample Drawing; Stencils. (86g) F2-04AD-1L 3. f2-02da. Radwell is not an authorized distributor, reseller or representative of the. JIC / NFPA Sample Drawing; IEC 60617 Sample Drawing; P&ID PIP Sample Drawing; Hydraulic Sample Drawing; Pneumatic Sample Drawing; Stencils. 0 oz. 888. It’s as simple as. Results 1 - 3 of 3. (80g) F2-02DA-2L 2. 2 oz. ABB; AC500 PLC COMM INT Modules;F2-02DA-1L 2-Ch 4-20 mA Analog Output <---> This module requires a 12 VDC user power supply for operation. (80g) F2-02DA-2 2. We're a great place to work! Check out our job. 00 2600 300 Power Consumed Device 5V(mA) 24V Auxiliary CPUs D2-230 120 0 D2-240 120 0 D2-250-1 330 0 D2-260 330 0 H2-WPLC*-** 680 0 DC Input Modules D2-08ND3 50 0 D2-16ND3-2 100 0 D2-32ND3 25 0 D2-32ND3-2 25 0 AC Input Modules D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0. f2-04ad-2 √ f2-08ad-1 √ f2-08ad-2 √ f2-02da-1 √ f2-02da-2 √ f2-02da-1l √ f2-02da-2l √ f2-02das-1 √ f2-02das-2 √ f2-08da-1 √ f2-08da-2 √ f2-4ad2da √ f2-04rtd √ f2-04thm √ f2-8ad4da-1 √ f2-8ad4da-2 √ intelligent module * d2-260 d2-262 d2-rmsm √ h2-ecom √ h2-ecom100 √ d2-dcm √ h2-ctrio √ d2-ctrint √ not. It’s as simple as. ABB; AC500 PLC COMM INT Modules; AC500 PLC COMM INT Modules - Layout;DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. 5 VAC (>0. Order toll free: 800. Items per page. Please call or email us with your request. 63 (0x3F) 2. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. . 5A F2-08T OUT 20-125 VA Derating Note: All outputs can be run at the current per point shown. F2-02DA-1 - DirectLOGIC DL205 analog output module, 2-channel, current, 12-bit, output current signal range(s) of 4-20 mA, external 24 VDC required. Do-more H2 F2-02DA-1 PLC AIO, 2AO, side view H2 PLC AIO Modules - Layout. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. 1--5 - Carnegie. ABB; AC500 PLC COMM INT Modules; AC500 PLC COMM INT Modules - Layout;F2–DEVNETS–1 DeviceNet Base Controller, 1st Edition Installing the F2–DEVNETS–1 The F2–DEVNETS–1 controller has a 8 jumpers which are used to set baud rates and the node address. F2-02DA-1L: Low-power CMOS design requires less than 70mA. DL205 PLCs tDL2-34 1-800-633-0405 For the latest prices, please check AutomationDirect. 8 oz. Reference: PLC1. Home; Products; Support; Downloads; Contact; Products. The power budget requirement is 40mA at 5VDC (supplied by the base). Search for Questions, Answers & Knowledge Articles1. 5500. F2-02DAS-1 OUTA NALOG 2CH F2-02DAS-1 12-32VDC ANALOG OUT 4-20mA +V1 +I1 N/C +V2 +I2 0V1 –I1 0V2 –I2 F2-02DAS-1 OUT ANALOG F2-02DAS-1 12-32VDC ANALOG OUT 4-20m Ch1 Max Load Impedance 525 ohms See NOTE 2 Ch2 Max Load Impedance 525 ohms See NOTE 2 See NOTE 3 Typical user wiring NOTE 1: Shields should be connected to the 0V terminal of the module. Locate your Drive and type of communications 2. Multiple model numbers may indicate different products, different components within the products or both. Back Shopping Cart (0) Support. Back to symbols. ZIPLink Wiring Solutions. The. (109g) F2-02DAS-2 3. 8 oz. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. com. Available operating ranges are 0--5V, 0--10V, 5V, and 10V. 00 This module requires a 24VDC user power supply for operation. com®. D0-16ND3 F2-DEVNETS FC-R1 Series DL205 FC-33 T1F-08DA-1 FC-11 FA-ISOCON F2-SDS-1 D0-06DD1-D F2-CP128 F2-UNICON F2-08TA D0-06DD2-D D0-06DD2 F2-DEVNETS-1 D2-HPP,. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. 00 This module requires a 24VDC user power supply for operation. Word 2 = Ch2 : No software configuration . • Outputs can be independently configured for any of the following ranges:. G Chapter Getting Started Analog Output Specification F2-02DA-1, (L) F2-02DA-2, (L) Channels 2 Output Ranges 4–20 mA 0–5 V, 0–10 V, ±5V, ±10V Resolution 12 bit (1 in 4096) Output Type Single ended See Chapter. Continuous Overload ±45 mA Input Impedance 100 0. 4 VDC 60 mA CH ANALOG OUT 0-10VDC 0-5VDC +V1 IN CH1 N/ +V2 CH 0V IN CH1-V N/ 0V2-V F2-02DAS-2 OUT ANALOG F2-02DAS-2 21. Kami adalah trading dan distributor lengkap juga harga murah dapat memenuhi semua kebutuhan industri di Indonesia. Sample Drawings. Do-more H2 F2-02DA-1 PLC Analog I/O modules, 2 analog output. It’s as simple as. Analog output module for Koyo DL205 and Do-more PLCSlot 1 = F2-8AD4DA-1 . D2-04BDC1-1 F2-04THM D2-06BDC1-1 F2-02DA-1(L) D2-09BDC1-1 F2-02DA-2(L) D2-06BDC2-1 F2-02DAS-1 D2-09BDC2-1 F2-02DAS-2 Discrete I/O Modules D2-08ND3 F2-08DA-1 D2-16ND3-2 F2-08DA-2 D2-32ND3 F2-4AD2DA D2-32ND3-2 F2-8AD4DA-1 D2-08NA-1 F2-8AD4DA-2 D2-08NA-2 Local Expansion Modules D2-CM No D2-16NA D2. The module maintains a database with all identifica-tion data, diagnostic information, and parameters that are configured within the 1. 35 shipping. Shopping Cart (0) Login. f2-02da-2. com. Multiple model numbers may indicate different products, different components within the products or both. EN. AutomationDirect F2-02DA-1 Installation And I/O Manual (122 pages) DirectLOGIC DL205 series. 00 2 ch. Fixed a problem in the Memory Configuration if the block size of DLX, DLY or DLC exceeded 1024. The default configuration for a Do-more controller is to automatically map the I/O points for all Analog I/O Modules, beginning in the slot adjacent to the controller, and proceeding from left to right across the base, allocating signed word input and signed word output memory as each module requires. 0. This catalog does not cover CPU-slot controllers. The module can be installed in any slot if either a DL240 CPU (firmware V1. This version of Internet Explorer is either no longer supported by Microsoft , or is obsolete and some features of our store may no longer be supported. Number of Channels 2 Output Ranges 0 to 5V, 0 to 10 V, ±5V, ±10 V Resolution 12 bit (1 in 4096) Output Type Single ended, 1. Led connector module zl-cm08l120 cables and plc i/o modules. It’s as simple as. F2-02DA-2L 2. Loading. Back Shopping Cart (0) Support; Home. com. Search: To search for a specific part number, use your browsers's "Find" feature by pressing "Ctrl+F" ("Command+F" on Mac systems) Enter the part number you're looking for, and you'll be taken right to the part number. Multiple model numbers may indicate different products, different components within the products or both. 1-8 DL205 Analog I/O Manual, 7th Edition, Rev. 00 2600 300 Power Consumed Device 5V(mA) 24V Auxiliary CPUs D2-230 120 0 D2-240 120 0 D2-250-1 330 0 D2-260 330 0 H2-WPLC*-** 680 0 DC Input Modules D2-08ND3 50 0 D2-16ND3-2 100 0 D2-32ND3 25 0 D2-32ND3-2 25 0 AC Input Modules D2-08NA-1 50 0 D2-08NA-2 100 0 D2-16NA 100 0 Input Simulator Module F2-08SIM. 1--5 - Carnegie. 2 oz. 450. 5 or later) or a DL250 CPU is used. 10-15vdc 70ma analog out 0-5vdc-5+5vdc +12v ch1+ ch2+ nc nc ch1– ch2– nc nc f2-02da-2l out analog 2ch. Chapter 6: Specifications - Analog I/O Modules F2-02DA-1(L), Analog Output Base Power Required F2-02DA-1(L) 2-Channel Analog Current Output 40mA 5VDC Number of Channels F2-02DA-1:18 to 30VDC, 60mA F2-02DA-1L: 10 to 15VDC, 70mA Output Ranges 4 to 20mA External Power Supply (Add 20mA for each current loop Resolution 12 bit (1 in 4096) F2-02DA-1: DirectLOGIC DL205 analog output module, 2-channel, current, 12-bit, output current signal range(s) of 4-20 mA, external 24 VDC required. Back Shopping Cart (0) Support. 00 Save as much as 69 % Last Value Update: 1/30/2023 Have you seen this for less?. . Brand:. Display #. AutomationDirect F2-02DA-2L Installation And I/O Manual (122 pages) DirectLOGIC DL205 series. Component: Do-more H2 F2-02DA-1 PLC AIO, 2AO. Search: To search for a specific part number, use your browsers's "Find" feature by pressing "Ctrl+F" ("Command+F" on Mac systems) Enter the part number you're looking for, and you'll be taken right to the part number. • *F2-02DA-2L: Low-power CMOS design requires less than 70mA from an external 12VDC power supply. All other specifications are the same. It also lacks hysteresis. F2-02DA-1(L) F2-02DA-2(L) Word 1 = Ch1 . 0 oz. o. Use this cross-reference table if you're looking for the equivalent PLC Direct parts for your "old" GE or TI/Siemens PLC system. (109g) F2-4AD2DA 4. If you need a specific firmware or series relating to F2 02DA 2, we probably have it. Toggle navigation. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. F2-02DA-2, F2--02DA--2L 2-Channel Analog Voltage Output DL205 Analog Manual 7th Ed. a Add To Cart. AutomationDirect F2-02DA-1L Installation And I/O Manual (122 pages) DirectLOGIC DL205 series. D0-16ND3 F2-DEVNETS FC-R1 Series DL205 FC-33 T1F-08DA-1 FC-11 FA-ISOCON F2-SDS-1 D0-06DD1-D F2-CP128 F2-UNICON F2-08TA D0-06DD2-D D0-06DD2 F2-DEVNETS-1 D2-HPP,. If you need a specific firmware or series relating to F2 02DA 2, we probably have it. TABLE OF CONTENTS Chapter 1 - Getting Started Introduction. All other specifications are the same. Resolution 12 bit (1 in 4096) Output Type Single ended, 1 common. 8 9 Analog OutputGeneral Information about the Product Part Number F2-02DA-1 F2 Description F2-02DA-1 by Facts Engineering Analog Output Module DL205 DirectLOGIC 205 Condition used Cleaned and Tested. F2-02DA-2L. 입력 8채널 0~5V/0~10V(12, 14,16bit). The output range is 4-20 mA. ET excluding holidays Career Opportunities. [Inputs: Selectable 16 bit, 14-bit, or 12-bit resolution, range: 0-20 mA. The module maintains a database with all identifica-tion data, diagnostic information, and parameters that are configured within theF2-SDS-1 FC-R1 F2-DEVNETS FC-11 ZL followed by -RTB or -RFU followed by 40. Mã sản phẩm (Model): F2-02DA-1L. Thời gian giao. If you are connecting to an existing DeviceNet network, you may need to change the DeviceNet. The. It’s as simple as. (86g) F2-08AD-2 4. The range of each channel can be independently set. Triple Port BASIC CoProcessor Module Specification Module Type CoProcessor, Intelligent Modules per CPU Seven maximum, any slot in CPU base (except slot zero) Communication 256 character type-ahead input buffer on all ports. Voted #1 mid-sized employer in Atlanta. f2-02da-2l. The module can be installed in any slot if either a DL240 CPU (firmware V1. The module is designed to operate in a wide temperature range, maintaining accurate analog output control in challenging industrial settings. ZIPLink Wiring Solutions. 8 oz. With 1 Year Warranty 1-800-991-7026 | 1-919-372-8413 | [email protected] oz. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. F2-02DA-22-Channel Voltage Analog Out One count in the specification table is equal to one least significant bit of the analog data value (1 in 4096). We have 1 AutomationDirect F2-02DA-1L manual available for free PDF download: Installation And I/O Manual . Analog I/O - F2-02DAS-2 analog output channel 1 is tied to the F2-04AD-2 analog input channel 1 of slot 3. 2-channel analog output module, 12-bit resolution, range 4-20 mA. EN. Order toll free: 800. 4-20 mA 24 V PLC Analog Output ModuleDo-more H2 F2-02DAS-1 PLC AIO, 2AO, side view H2 PLC AIO Modules - Layout. DL205 analog output module, 2-channel, current, 12-bit, output current signal range (s) of 4-20 mA, external 12 VDC required. Code Definition; FN: Factory New. 5 m, -1 = 1. Do not use the shield or drain wire for the third connection. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. Search Product. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. How it works The F2-SDS-1 module plugs into the CPU slot of any DL205 I/O base. 0 oz. 884. F2-08DA-2 - DirectLOGIC DL205 analog output module, 8-channel, voltage, 12-bit, output voltage signal range(s) of 0-5 VDC and 0-10 VDC, external 24 VDC. Rev. No. Multiple model numbers may indicate different products, different components within the products or both. 00 Input Channels per Module 8, single ended (one common). Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. 1 To make a custom cable for the 32-point modules, use: Solder-style 180° connector ZL-D24-CON or Solder-style 45° connector ZL-D24-CON-X. (80g) F2-02DA-2 2. NOTE 1: Shields should be connected to the 0V of the module or the OV of the R/S. B endi rodut eiht ales DL205 Product Weight Table Analog Modules Weight F2-04AD-1 3. F2-02DA-1L 2-Channel 4-20Ma Analog Output Module. com. F2-02DA-1L 40 70 @ 12V (note 1) F2-02DA-2 40 60 F2-02DA-2L 40 70 @ 12V F2-02DAS-1 F2-02DAS-2 100 100 50 / channel 60 / channel F2-08DA-1 30 50 (note 1) F2-08DA-2 60 140 F2-4AD2DA 60 80 (note 1) F2-8AD4DA-1 35 100 (note 1) F2-8AD4DA-2 35 80 (note 1) F2-04RTD 90 0 F2-04THM 110 60 Specialty Modules D2-CTRINT 50* 0Model Number(s) Model numbers included in the listing. 79 (0x4F) 8. EN. 2-7F2-02DA-12-Channel 4-20mA Analog Out One count in the specification table is equal to one least significant bit of the ana-log data value (1 in 4096). 6-26. 00 2 ch. condition: used & working . Shop Online . JIC / NFPA Sample Drawing; IEC 60617 Sample Drawing; P&ID PIP Sample Drawing; Hydraulic Sample Drawing; Pneumatic Sample Drawing; Stencils. This document also may not show all models included in the listing. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. SKU: F2-02DA-1 F2-02DA-1 . . 5 inches; 1. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. All other specifications are the same. 0 m. 8 oz. Back to symbols. At the sensor's maximum 20. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. . See the F2-02DA-1 on the previous page if you want to use a 24VDC supply. Module Specifications The F2-02DA-1 and F2-02DA-1L Analog Output modules provide several hardware features: Analog outputs are optically isolated from the PLC logic. 2 oz. (Nicolas Tucat/AFP via Getty Images). The available power budget and discrete I/O points are the limiting factors. Created Date: May 18,2006. 0-5V, 1Note: Cable part number denotes compatibility between Connector Module and I/O Modules. Need help selecting a PLC family? Use our configuration tool to configure and order. 7. facts engineering f2-02da-2 analog output module june 14, 2023 get link; facebook; twitter; pinterest; email; other apps; we are pleased to offer facts engineering f2-02da-2 analog output module . 8 oz. Analog output module for Koyo DL205 and Do-more PLCF2-02DA-1L2-Ch 4-20mA Analog Output This module requires a 12 VDC user power supply for operation. See the F2-02DA-1L on the next page if you want to use a 12VDC supply. Analog output module for Koyo DL205 and Do-more PLC. F2-02DA-1 PLCs/Machine Control from FACTS ENGINEERING In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - OUTPUT MODULE, DL205, ANALOG, 2-CHANNEL, CURRENT, 12-BIT, OUTPUT CURRENT SIGNAL RANGE(S) OF 4-20 MA, EXTERNAL 24 VDC REQUIRED. The Facts Engineering F2-02DA-1 Output Module has a 2-channel analog output, 12-bit resolution and an output range of 4 to 20 mA. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. Multiple model numbers may indicate different products, different components within the products or both. ZIPLink 20-pole feedthrough module. F2-02DA-1 Controls & Indicators from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DIRECTLOGIC DL205. Expansion bases are commonly used when there are not enough slots available in the CPU base, when the base power budget will bePLC DIRECT F0-2AD2DA-2. 2 Caution: The D2-04TD1, D2-04TRS, and F2-08TRS outputs are derated not to exceed module specs F2-02DA-1 40 60 (note 1) F2-02DA-1L 40 70 @ 12V (note 1) F2-02DA-2 40 60 F2-02DA-2L 40 70 @ 12V F2-02DAS-1 F2-02DAS-2 100 100 50 / channel 60 / channel F2-08DA-1 30 50 (note 1) F2-08DA-2 60 140 F2-4AD2DA 60 80 (note 1) F2-8AD4DA-1 35 100 (note 1) F2-8AD4DA-2 35 80 (note 1) F2-04RTD 90 0 F2-04THM 110 60 Specialty Modules D2-CTRINT 50* 0 D2-CM. Multiple model numbers may indicate different products, different components within the products or both. (86g) F2-04AD-2 3. Specifications. F2-02da-1 3D models ready to view, buy, and download for free. Number of Channels 2 Output Ranges 0 to 5V, 0 to 10 V, ±5V, ±10 V Resolution 12 bit (1 in 4096) Output Type Single ended, 1. Thông tin sản phẩm (Koyo F2-02DA-1L) Tên sản phẩm: Mô đun Analog (DL-205) 2AO A Koyo – F2-02DA-1L. aa eeD2-04BDC1-1 $274. 2 Pounds; Date First Available. . Brand: AutomationDirect. This document also may not show all models included in the listing. ANALOG VOLTAGE OUTPUT MODULES. The range of each channel can be independently set. 0-5V, 0-10V, -5 to +5V, -10 to +10V F2-02DA-1L $155. J–8 DL205 User Manual, 5th Edition, Rev. Toggle navigation. Created and manufactured by AutomationDirect to be a compatible product with DirectLOGIC 205 series systems, the F2-02DA-2 module is a 2-channel analog voltage output module. . NOTE 1 60mA +24V CH1--CH1+ CH2--CH2+ NC NC NC NC 18--30VDC 60mA F2--02DA--1 OUT ANALOG F 2--02DA--1 2CH ANALOGOUT 4--20mA 0V CH1--CH2--CH1+ CH2+. Open load 3. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. Analog I/O - F2-02DAS-2 analog output channel 1 is tied to the F2-04AD-2 analog input channel 1 of slot 3. 4 VD CH ANALOG OUT. NOTE 1: Shields should be connected to the 0V of the module or the OV of the R/S. • F2-02DA-2: Low-power CMOS design requires less than 60mA from an external 24VDC power supply. EN. Back Shopping Cart (0) Support; Home. The F2-02DA-1 (L) Analog output appears as a 16-point discrete output module. . (F2-02DA-1) T1H Series Analog I/O Modules The Do-more T1H series PLC supports all the analog I/O modules available in the Terminator I/O product line. F2-02DA-1L 40 70 @ 12V (note 1) F2-02DA-2 40 60 F2-02DA-2L 40 70 @ 12V F2-02DAS-1 F2-02DAS-2 100 100 50 / channel 60 / channel F2-08DA-1 30 50 (note 1) F2-08DA-2 60 140 F2-4AD2DA 60 80 (note 1) F2-04RTD 90 0 F2-04THM 110 60 Specialty Modules D2-CTRINT 50* 0 D2-CM / D2-EM 100/130 0 H2-CTRIO 400 0 D2-DCM 300 0F2-SDS-1 Slave F2-SDS-1 Slave Connect our micro-modular DL205 I/O… Ask for our D2-INST-M Installation and I/O Manual for complete information about DL205 I/O modules, power budgeting, and installation and wiring. 00 2 ch. 8 oz. F2-02DA-2 OUTA NALOG 2CH F2-02DA-2 18-30VDC 60mA ANALOG OUT 0-5VDC-5-+5VDC 0-10VDC-10-+10VDC +24V CH1+ CH2+ NC NC 0V CH2– NC NC F2 -02DA 2 OUT ANALOG 18-30VDC 60mA ANALOG OUT 0-5VDC-5-+5VDC 0-10VDC-10-+10VDC Typical user wiring Internal module wiring Transient protected precision digital to analog converter output circuits F2-02DA-2L OUTA NALOG 2CH F2-02DA-2L 10-15VDC 70mA ANALOG OUT 0-5VDC-5+5VDC +12V CH1+ NC NC CH1– CH2– NC F 2-02DA- L OUT ANALOG F2-02DA-2L 10-15VDC 70m ANALOG OUT 0-5VDC - 5+ VDC Typical user wiring Internal module wiring Transient protected precision digital to analog converter output circuits NOTE 1: Shields should be connected to the 0V. (65g)DL205 아날로그 입출력 모듈. 2 Channel, Voltage. EN. Multiple model numbers may indicate different products, different components within the products or both. Use this cross-reference table if you're looking for the equivalent PLC Direct parts for your "old" GE or TI/Siemens PLC system. ABB; AC500 PLC COMM INT Modules;Module=”F2-02DA-2L 2CH ANALOG OUTPUT” 0x61 EndModule Module=”F2-02DAS-1 2CH ANALOG OUTPUT” 0x61 EndModule Module=”F2-02DAS-2 2CH ANALOG OUTPUT” 0x61 EndModule Module=”F2-08DA-2 8CH ANALOG OUTPUT” 0x67 EndModule Module=”F2-08DA-1SS 8CH ANALOG OUTPUT” 0x67 EndModule. Home; Products; Support; Downloads; Contact; Products. F2-8AD4DA-1 8-Channel Analog Current Input 4-Channel Analog Current Output $634. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. aa eeF2–02DA–2 F2–02DA–2L F2–02DAS–1 F2–02DAS–2 F2–08DA–1 F2–08DA–2 Combination Modules F2–04AD2DA Specialty Modules H2–CTRIO. None : F2-02DAS-1 . 00 Number of Channels 8, single ended (1 common) Input Ranges 4 to 20 mA current Resolution 12 bit (1 in 4096). Open to Making bulk Deals. 4-20mA, 16-bit isolated F2-02DAS-2 $255. DL205 PLCs tDL2-77 1-800-633-0405 For the latest prices, please check AutomationDirect. Tags: Do-more, Programmable Logic Controllers (PLC) Edit. 2 ch analog output, voltage, 12 bit resolution. (118g) F2-04RTD 3. F2-02DA-1 2-Channel 4-20 mA Analog Output $164. Model Number(s) Model numbers included in the listing. Back to symbols. DL205 PLCs tDL2-45 1-800-633-0405 For the latest prices, please check AutomationDirect. Module Specifications The F2-02DA-1 and F2-02DA-1L Analog Output modules provide several hardware features: Analog outputs are optically isolated from the PLC logic. See the F2-02DA-1L on the next page if you want to use a 12 VDC supply. Number of Channels 2 Output Ranges 4 to 20 mA Resolution 12-bit (1 in 4096) Output Type Single ended, one common Digital Output Points 16 (Y) output points Required (12 binary data bits, 2 channel ID bits) Maximum Loop Supply 30VDC F2-02DA-1 2-Channel 4-20mA Analog Output $282. F2--02DA--1 2CH ANALOGOUT 4--20mA 0V SureServo Drive ±10 V Analog Input TM +-10-10 OUT (V) 0 20 INPUT (mA) 41 2 24V 0V V+ I+ COM ±mV COM ±5V ±10V ±15V DIAG CAL FC-35B COM Set For 4-20 mA Input ±10 V Output *CAUTION: Product may be damaged if multiple outputs are tied together. (86g) F2-08AD-1 3. F2-02DA-1 - F2-02DA-1 by Automation Direct Analog Output Module DL205 DirectLOGIC 205 - used General Information about the Product Part Number F2-02DA-1 F2. See the F2-02DA-2 on the previous page if you want to use a 24 VDC supply. F2-02DA-1 - 2 ch. 0 oz. 00 2600 None D2-06B-1 $268. Sample Drawings. type: analog output module . Model Number(s) Model numbers included in the listing. ACInputModules F2–02DA–1 40 60** D2–08NA–1 50 0 F2–02DA–1L 40 70mA@12V* D2–08NA–2 100 0 F2–02DA–2 40 60 D2–16NA 100 0 F2–02DA–2L 40 70mA@12V* DCOutputModules F2–08DA–1 30 50mA* D2–04TD1 60 20 F2–08DA–2 60 140 D2–08TD1(–2) 100 0 F2–02DAS–1 100 50mAperchannelF2-02DA-1L F2-02DA-2L F2-4AD2DA F2-8AD4DA-1 F2-8AD4DA-2 F2-02DAS-1 F2-02DAS-2 F2-08DA-1 F2-08DA-2 F2-04RTD F2-04THM 8 X/4 WX 8 X/4 WX 8 X/8 WX 8 X/8 WX 2 WY 2 WY 8 X/4 WX/2 WY 8 X/8 WX/7 WY 8 X/8 WX/7 WY 2 WY 2 WY 8 WY 8 WY 8 X/4 WX 8 X/4 WX AC OUTPUT D2-08TA F2-08TA D2-12TA 8 Y 8 Y 16 Y2 Note 1: 4-pt. com. Phone number: 1-877-854-3577 — Email:D2-06B-1 $176. We Offer Fast Same-Day Shipping Today! Click to Check if In-Stock. F2-02DA-2 specifics: 2 Analog outputs (voltage) 12-bit resolution; Specifications Quantity per product 1 Short Description. Add to Cart. Parts manufactured by then OEM and includes manufacturer certification. F2-02DA-2. Toggle navigation. Specifications. ABB; AC500 PLC COMM INT Modules;The F2-02DA-1 (L) Analog output appears as a 16-point discrete output module. 00 2600 300 D2-09BDC2-1 $359. Analog Voltage Output Modules F2-02DA-2L 2-Channel Voltage Analog Output <---> This module requires a 12 VDC user power supply for operation. F2-02DA-2. Ethernet Remote I/O Client Modules Overview The Ethernet Remote Client H2-ERM100 connects D2-262 CPU systems to Server I/O over a high-speed Ethernet link. 00 2 ch. The resolution is 12 bit (1 in 4096). All other specifications are the same. 8 Channel, Current. See the F2-02DA-1 on the previous page if you want to use a 24VDC supply. 00 2600 None D2-06B-1 $268. d2-09b-1 direct logic 205 base ( 9 slots) slot #0: dl260cpu slot #2: h2-erm ethernet remote master slot #3: d2-08nd3 input slot #4: f2-02da-2 0-10vdc output thanks Expand Post DL SeriesPLC Update Rate : 1 channel per scan maximum (D2--230 CPU) 2 channels per scan maximum (D2--240/250--1/260 CPU) Digital outputs : 12 binary data bits, 2 channel ID bits; Output points required : 16 point (Y) output module; Power Budget Requirement : 40 mA @ 5 VDC (supplied by base) External Power Supply : F2--02DA--1: 18-30 VDC, 60 MaF2-02DA-1 Controls & Indicators from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DIRECTLOGIC DL205 ANALOG OUTPUT MODULE, 2-CHANNEL, CURRENT, 12-BIT, OUTPUT CURRENT SIGNAL RANGE(S) OF 4-20 MA, EXTERNAL 12-24 VDC REQUIRED. F2-02DA-1L2-Ch 4-20mA Analog Output This module requires a 12 VDC user power supply for operation. F2-02DA-1 PLCs/Machine Control from FACTS ENGINEERING In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - OUTPUT. . Placement is determined by the available power budget and discrete I/O points. Number of. F2-02DA-2 PLCs/Machine Control from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - ANALOG OUTPUT MODULE, DIRECTLOGIC DL205, 2-CHANNEL, 12-BIT, OUTPUT VOLTAGE SIGNAL RANGE (S): 0-5 VDC / 0-10 VDC, EXTERNAL. (80g) F2-02DA-1L 2. Wiring Solutions Wiring Solutions using the ZIPLink Wiring System ZIPLinks eliminate the normally tedious process of wiring between devices by utilizing prewired cables and DIN rail mount connector modules. com. F2-02DA-1: Low-power CMOS design requires less than 60mA from an external 18- -30 VDC power supply. Shopping Cart (0) Login. Multiple model numbers may indicate different products, different components within the products or both. D2-06B-1 $176. Number of Channels 2 Output Ranges 4 to 20 mA Resolution 12-bit (1 in 4096) Output Type Single ended, one common Digital Output Points Required 16 (Y) output points (12 binary data bits, 2 channel ID bits) Maximum Loop Supply 30VDC. Model Number(s) Model numbers included in the listing. F2-02DA-1L: Low-power CMOS design requires less than 70mA from an external 10- -15 VDC power supply.